CIP/SIP Alarms
The following alarms apply to the CIP/SIP process. For detailed information about the CIP/SIP process, see “CIP(Clean-in-Place)”on page159 and “SIP(Steam-in-place)” on page 161.
General Alarms
The following alarms apply to both webs and will appear in the center alarm box (third from left) at the top of the CIP/SIP screen.
Alarm
To clear
Possible Causes
CIP/SIP Cycle cancelled
Press STOP CIP or STOP SIP button at end of cycle
CANCEL CIP/SIP CYCLE button pressed
WEB-Specific Alarms
The following alarms will apply to either Web1 or Web 2and will appear on either the lest side or the right side of the CIP/SIP screen.
Alarms
To clear
Possible cause on web 1
Possible cause on web2
Filler 1 CIP/SIP Interrupted
Press STOP CIP or SIP
button at end of cycle
STOP CIP/SIP FILLER1 button pressed
CANCEL CIP/SIP
CYCLE button pressed
Does not appear on Web1
Filler 2 CIP/SIP Interrupted
Press STOP CIP or SIP
button at end of cycle
STOP CIP/SIP FILLER2 button pressed
CANCEL CIP/SIP
CYCLE button pressed
Does not appear on Web2
Filler 3CIP/SIP Interrupted
Press STOP CIP or SIP
button at end of cycle
Does not appear on Web1
STOP CIP/SIP FILLER3 button pressed
CANCEL CIP/SIP
CYCLE button pressed
Filler 4CIP/SIP Interrupted
Press STOP CIP or SIP
button at end of cycle
Does not appear on Web2
STOP CIP/SIP FILLER4 button pressed
CANCEL CIP/SIP
CYCLE button pressed
Trackers Alarms
The following alarms apply to the trackers module. they will pertain to either web 1 or web 2 and will appear on either the left side or the right side of the Trackers screen. For detailed information about the trackers, see” Input Trackers Modules” on page 93 and “Output Tracker modules” on page 124.
Alarm
To clear
Possible cause on web 1
Possible cause on web 1
Input Tracker In Limit
Press the alarm touch button
WEB 411
AccuWeb#1
WEB 450
AccuWeb#2
Input Tracker out Limit
Press the alarm touch button
WEB 411
AccuWeb#1
WEB 450
AccuWeb#2
Input Tracker Faulted
Press the alarm touch button
WEB 411
AccuWeb#1
WEB 450
AccuWeb#2
Output Tracker In Limit
Press the alarm touch button
WEB 1011
AccuWeb#3
WEB 1050
AccuWeb#4
Output Tracker Out Limit
Press the alarm touch button
WEB 1011
AccuWeb#3
WEB 1050
AccuWeb#4
Output Tracker Faulted
Press the alarm touch button
WEB 1011
AccuWeb#3
WEB 1050
AccuWeb#4
Side Seal Alarms
The following alarms apply to the Side Seal modules. For detailed information about the Side Seal modules, see ”Side Seal Module” on page 94.
General Alarms
The following alarms apply to both webs and will appear in the center alarm box (third from left) at the top of the Side Seal screen.
Alarm
To clear
Possible Causes
Upper Platten Not Open
Press the alarm touch button
CS 3848
SOL 4005
Upper Platten Cylinders
Upper Platten Not Open
Press the alarm touch button
CS 3853
SOL 4005
Upper Platten Cylinders
Upper Platten Not Open
Press the alarm touch button
CS 3856
SOL 4007
Lower Platten Cylinders
Upper Platten Not Open
Press the alarm touch button
CS 3860
SOL 4007
Lower Platten Cylinders
Web-Specific Alarms
The following alarms will apply to either Web 1 or Web 2and will appear on either the left side or the right side the Side Seal screen.
Alarm
To clear
Possible Causes on Web1
Possible Causes on Web2
Upper Left Heater Open
Correct the fault
Upper Left Heater Open
SSR 1
INS 1
Upper Left Heater Open
SSR 5
INS 5
Upper Left Thermocouple
Open
Correct the fault
TC 1
INS 1
TC 5
INS 5
Upper Right Heater Open
Correct the fault
Upper Right Heater Open
SSR 2
INS 2
Upper Right Heater Open
SSR 6
INS 6
Upper Right Thermocouple
Open
Correct the fault
TC 2
INS 2
TC 6
INS 6
Alarm
To clear
Possible Causes on Web1
Possible Causes on Web2
Lower Left Heater
Open
Correct the fault
Lower Left Heater Open
SSR 3
INS 3
Lower Left Heater Open
SSR 7
INS 7
Lower Left Thermocouple
Correct the fault
TC 3
INS 3
TC 7
INS 7
Lower Right Heater
Open
Correct the fault
Lower Right Heater Open
SSR 4
INS 4
Lower Right Heater Open
SSR 8
INS 8
Lower Left Thermocouple
Correct the fault
TC 4
INS 4
TC 8
INS 8
Printer Alarms
The following alarms apply to the Printer module. For detailed information about the Printer module, see “Printer Module” on page 106.
General Alarms
The following alarms apply to both webs and will appear in the center alarm box (third from left) at the top of the Printer screen.
Alarm
To clear
Possible Causes
Printer Not Open
Press the alarm touch button
CS 3863
SOL 4017
Printer Platten Cylinders
Printer Not Closed
Press the alarm touch button
CS 3863
SOL 4017
Printer Platten Cylinders
Web-Specific Alarms
The following alarms apply to either Web 1 or Web 2and will appear on either the left side or the right side of the Printer screen.
Alarm
To clear
Possible Causes on Web1
Possible Causes on Web1
Heater Open
Correct the fault
Printer Heater Open
INS 9
SSR 9
Printer Heater Open
INS 10
SSR 10
Thermocouple Open
Correct the fault
TC 9
INS 9
TC 10
INS 10
Print Media Move Not
completed
Press the alarm touch button
DRV 739
OB 1201
DRV 839
OB 1220
Print Media Move Not
Enabled
Press the alarm touch button
DRV 739
OB 1201
DRV 839
OB 1220
Print media Unwind Chuck
Correct the fault
PS 3910
SOL 3953
PS 3916
SOL 3953
Print media Rewind Chuck
Correct the fault
PS 3918
SOL 3955
PS 3921
SOL 3960
Print media Empty or Broken
Press the alarm touch button
PROX 3904
PROX 3908
Top Seal Alarms
The following alarms apply to the Top Seal module. For detailed information about the Top Seal module, see “Top Seal Module” on page 115.
General Alarms
The following alarms apply to both webs and will appear in the center alarm box (third from left) at the top of Top Seal screen.
Alarm
To clear
Possible Causes
Upper Platten Not Open
Press the alarm touch button
CS 3923
SOL 4019
Upper Platten Cylinders
Upper Platten Not Closed
Press the alarm touch button
CS 3927
SOL 4019
Upper Platten Cylinders
Lower Platten Not Open
Press the alarm touch button
CS 3930
SOL 4019
Upper Platten Cylinders
Lower Platten Not Closed
Press the alarm touch button
CS 3934
SOL 4019
Upper Platten Cylinders
Web-specific Alarms
The following alarms apply to either Web 1 or Web 2 and will appear on either the left side or the right side of the Top Seal screen.
Alarm
To clear
Possible Causes on Web1
Possible Causes on Web1
Upper Heater Open
Correct the fault
One of the Upper
Heaters is Open
INS 11
SRR 11
One of the Upper
Heaters is Open
INS 13
SRR 13
Upper Thermocouple Open
Correct the fault
TC 11
INS 11
TC 13
INS 13
Lower Heater Open
Correct the fault
One of the Lower
Heaters is Open
INS 12
SRR 12
One of the Lower
Heaters is Open
INS 14
SRR 14
Alarm
To clear
Possible Causes on Web1
Possible Causes on Web1
Lower Thermocouple Open
Correct the fault
TC 12
INS 12
TC 14
INS 14
Film Feed Alarms
The following alarms apply to the Film Feed module. They pertain to either Web 1 or Web 2 and will appear on either the left side or the right side of the Film Feed screen. For detailed information about the Film Feed module, see “Film Feed Module” on page 125.
Alarm
To clear
Possible Causes on Web2
Possible Causes on Web2
Film Feed Move Not
complete
Press the alarm touch button
DRV 1000
OB 1201
DRV 1139
OB 1220
Film Feed Servo Not
Enabled
Press the alarm touch button
DRV 1000
OB 1201
DRV 1139
OB 1220
Film Feed Roller Open
Press the alarm touch button
PROX 3117
SOL 3732
PROX 3119
SOL 3730
Film Jammed at Die Cut
Press the alarm touch button
PE 3112
PE 3114
Die Cut Alarms
The following alarms apply to the Die CUT module. They pertain to both webs and will appear in the center alarm box at the top of the Die Cut screen. For detailed information about the Die Cut module, see “Die Cut Module” on page 126.
Alarm
To clear
Possible causes
Cutting Die Not Open
Press the alarm touch button
CS 3124
SOL 3744
Cutting Die Cylinders
Cutting Die Not Closed
Press the alarm touch button
CS 3127
SOL 3744
Cutting Die Cylinders
Bag Clamp Open at Die Cut
Press the alarm touch button
PROX 3140A or PROX 314OB
SOL 3547
Cutting Die Cylinders
機(jī)械工程系 第17頁(yè) 共42頁(yè)
收藏
編號(hào):12246645
類型:共享資源
大小:38.50KB
格式:RAR
上傳時(shí)間:2020-05-08
5
積分
- 關(guān) 鍵 詞:
-
機(jī)械類畢業(yè)論文中英文對(duì)照文獻(xiàn)翻譯
word英文1473字14頁(yè),word中文翻譯1859字13頁(yè)
【機(jī)械類畢業(yè)論文中英文對(duì)照文獻(xiàn)翻譯】CIP
SIP
警告【word英文1473字14頁(yè),word中文翻譯1859字13頁(yè)】
機(jī)械類
- 資源描述:
-
【機(jī)械類畢業(yè)論文中英文對(duì)照文獻(xiàn)翻譯】CIP SIP 警告【word英文1473字14頁(yè)word中文翻譯1859字13頁(yè)】,機(jī)械類畢業(yè)論文中英文對(duì)照文獻(xiàn)翻譯,word英文1473字14頁(yè),word中文翻譯1859字13頁(yè),【機(jī)械類畢業(yè)論文中英文對(duì)照文獻(xiàn)翻譯】CIP,SIP,警告【word英文1473字14頁(yè),word中文翻譯1859字13頁(yè)】,機(jī)械類
展開閱讀全文
- 溫馨提示:
1: 本站所有資源如無(wú)特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
2: 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
3.本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
5. 裝配圖網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
裝配圖網(wǎng)所有資源均是用戶自行上傳分享,僅供網(wǎng)友學(xué)習(xí)交流,未經(jīng)上傳用戶書面授權(quán),請(qǐng)勿作他用。